Author: Morgan Zych
Contents
Materials
- Xylenes
- Ensure xylenes are handled under sufficient ventilation (fume hood).
- 100% ethanol
- 95% ethanol
- If more 95% ethanol is needed, dilute by adding 41.2mL distilled water to unopened 4L jug of 100% ethanol
- Distilled water
- 3% Peroxide Solution
- Antigen retrieval solution
- Sodium citrate solution (IHCWorld):
- Add 2.94g trisodium citrate to 1000 mL distilled water (milliQ).
- Adjust pH to 6.0 or 9.0 (application dependent) using test strips by adding very small amounts of HCl (if too acidic, recover with very tiny amount of NaOH).
- Add 0.5mL Tween.
- Sodium citrate solution (IHCWorld):
- Casein blocking buffer
- Tween 20
- Unconjugated primary antibodies
- HRP-conjugated secondary antibodies
- Humidity chamber
- PBS (Stock or 10x)
- DAB kit
- Carcinogenic. Handle with care & avoid contact.
- Hematoxylin
- Bluing buffer (0.1% sodium bicarbonate)
- Permount slide mounting medium
Day One
- Label all slides w/ pencil.
- For organoids: do not use slide warmer as it disrupts organoid integrity.
- For tissues: slide warmer can be used but may cause sections to fall from slides more easily.
- Dewax slides by incubate slides in series of 2 buckets of xylenes for 10 minutes each, 2 buckets of 100% ethanol for 5 minutes each, and 2 buckets of 95% ethanol for 5 minutes each.
- Incubate slides in bucket of distilled water for 10 minutes
- While slides incubate in water, make 3% peroxide solution by adding 10mL of 30% stock peroxide to a small bucket and filling bucket up to 100mL line with distilled water.
- Incubate slides in bucket of peroxide for 10 minutes
- Blocks endogenous peroxidase activity to allow specificity of DAB reaction.
- While slides incubate in peroxide, fill vegetable steamer up to maximum line with distilled water and turn steamer on.
- Preheat steamer ~10 minutes.
- Move slides to a bucket of appropriate antigen retrieval solution*, place bucket in steamer, and steam for one hour.
- After antigen retrieval steam, allow slides to cool in freezer, then transfer to a bucket of room temperature distilled water.
- While slides cool, dilute antibodies in diluent of casein buffer supplemented with 1% Tween.
- Casein blocks nonspecific antibody binding.
- Tween increases antibody access to epitopes.
- Place moistened paper towels inside of humidity chamber and flatten them within grooves to accommodate slides.
- While slides cool, dilute antibodies in diluent of casein buffer supplemented with 1% Tween.
- Working one slide at a time:
- Blot water off of slides at a site far from the sample.
- Draw a wide circle (at least 1cm gap between circle + organoids) around sample with hydrophobic pen.
- Do not press too hard with pen.
- Ensure each circle is complete.
- Allow pen to dry very briefly then transfer slide into humidity chamber.
- Add 200mL of diluted antibody or control solution (diluent only) to each slide.
- If necessary, gently disperse antibody solution with pipette tip just contacting the solution itself, not touching the sample/slide!
- Place lid on humidity chamber and carefully move the chamber to the +4oC fridge for overnight incubation of primary antibodies.
Day Two
- Prepare three 250mL wash buckets by adding 25mL of 10X PBS to each bucket, then topping each bucket up to the 250mL line with distilled water.
- Add 2.5mL Tween (1%) as well to the middle bucket in the series of three washes.
- Take slides out of the humidity chamber and check to make sure none of the slides became dry overnight.
- If this occurred, make a note of which samples this happened to and consider removing from analysis.
- Move slides to a slide rack while holding the rack above the first wash bucket so that the liquid on the slides is caught by the bucket. Place in this bucket for 5 minutes.
- Wash in second (Tween-containing) and then third bucket for 5 minutes each.
- Set a timer for 30 minutes. Blot the first slide and apply minimum necessary amount of drops of species-appropriate secondary antibody onto it. Start the timer and apply secondary antibody to each subsequent slide in regular intervals (30 seconds, 1 minute, whatever works) keeping the slides in a line in the order they received secondary antibody.
- Incubate at room temperature.
- Disperse antibodies with pipette tip if necessary.
- While secondary antibodies incubate, prepare all materials needed to finish slide prep:
- Make DAB solution by calculating the volume needed to apply 200mL per slide, then adding 30mL DAB enzyme for every 1000mL of DAB diluent needed. Invert tube repeatedly to mix
- Fill a 100mL bucket with tap water (NOT distilled this time) and place slide rack into tap water so it is ready.
- Place kimwipes or white piece of paper near this bucket for checking DAB development.
- Empty a wash bucket, rinse, and fill it to the 250mL line with tap water. Place beside hematoxylin in fume hood.
- Fill 2 buckets each with 95% ethanol, 100% ethanol, and xylenes.
- Transfer slides into rack and into the first wash bucket at the same time interval as you applied secondary antibody.
- This ensures that each slide incubates with secondary antibody for a full 30 minutes.
- When each slide has been placed in the rack in the first wash bucket, perform all 3 washes for 5 minutes each.
- Reset timer. Choose which slide should receive DAB first; if optimizing, choose the most concentrated antibody prep. Do not use control as first slide. Add 200mL DAB solution to this slide and start the timer.
- As with secondary antibody application, add DAB solution to each subsequent slide at a regular time interval
- Check DAB development as you go! Amount of time needed with DAB is variable but usually within 2-7 minutes.
- When DAB development is sufficient, place slides into rack in the tap water bucket. Tap water stops the DAB reaction.
- Stop DAB reaction after each slide has incubated for the same amount of time by adding them to the bucket at the same time interval DAB was applied.
- Consider working with a partner if processing large numbers of slides.
- When all slides have been placed into the tap water bucket, transfer loaded rack into the hematoxylin bucket in the fume hood and incubate for two minutes.
- Move slides into bucket of water. Bring this bucket to the sink and replace water + wash slides until water is clear.
- Do not let slides come into contact with the running tap.
- Dip rack of slides into bucket of bluing buffer 7 times.
- Clear slides by dipping them 15 times each in 2 buckets of 95% ethanol, 2 buckets of 100% ethanol, and 2 buckets of xylenes in that order. Leave slide rack in final xylene bucket while mounting slides
- With small pestle put Permount on the slide encircling the sample. Squish slide cover on and press to disperse Permount on top of sample and to push any bubbles away.
- Keep in the fume hood
- Wait at least 2 hours, then gently clean slides with kimwipe dipped in xylene.
- Wait a few hours more until all xylenes have evaporated and mounting media is completely hardened before viewing/imaging
Last updated: 02/2025